Description
Product Specifications
Display
Size: 5.8-inch (diagonal)
Type: Monochrome LCD; optional color LCD
Resolution: 320 by 240 pixels
Number of traces: 3
Number of seconds/trace: 3.8 at 25 mm/sec
Sweep speed: 25 mm/sec (with erase bar)
Information window: Displays non-real-time information without obstructing the display of real-time information
Display organization: Prioritized by parameter
Controls
Trim Knob control
Five hard keys: Silence Alarm, Graph Go/Stop, NBP Go/Stop, Function, and Power On/Off
Alarms
Categories: Patient status and system status
Priority: 4 levels – Crisis, Warning, Advisory, Message
Notification: Audible and visual
Setting: Default and individual
Silencing: 1 minute, current alarm only
Pause: 5 minutes in Adult ICU mode, 3 minutes in Neonatal ICU mode, and 5 minute, 15 minute, or permanent pause in OR mode
Volume: Default 70%, 70 dB measured at 1 meter
ECG
Standard leads available: I, II, III, V, aVR, aVL, and aVF
Leads analyzed simultaneously: I, II, III, and V (multi-lead mode)
Lead fail: identifies failed lead
Alarms: User-selectable upper and lower heart rate limits
Input specifications
Voltage range: ±0.5 mV to ±5 mV with size 2x or 4x below 1 mV and with QRS width Adult ICU 70 to 120 ms Neonatal ICU 40 to 80 ms
Signal width: 40 ms to 120 ms (Q to S)
Heart rate range: 30 to 300 bpm
Input impedance:
Common mode: > 10 M* at 50/60 Hz
Differential: > 2.5 M* from dc to 60 Hz
Common mode rejection: 90 dB minimum at 50 or 60 Hz
Output specifications
Frequency response:
Display:
Diagnostic: 0.05 to 40 Hz
Monitoring: 0.05 to 40 Hz
Moderate: 0.05 to 25 Hz
Maximum: 5 to 25 Hz
Paper:
Recorder:
Diagnostic: 0.05 to 100 Hz
Monitoring: 0.05 to 40 Hz
Moderate: 0.05 to 25 Hz
Maximum: 0.05 to 25 Hz
Noise: <30 µV RTI (referred to input)
Pacemaker detection/rejection
Input voltage range: ±2 mV to ±700 mV
Input pulse width: 0.1 to to 2 ms
Rise time: 10 ms to 100 µs
Over/under shoot: 2 mV (max.) with Diagnostic or Monitor filter setting and size 1x or 0.5x
Baseline drift: <0.5 mV/hour with a ±700-mV, 2-ms pacemaker pulse applied
Respiration
Measurement technique: Impedance variation detection
Range:
Respiration rate: 0-200 breaths per minute
Base impedance: 100-1000 * at 52.6 kHz
Detection sensitivity: 0.4 to 10 * variation
Waveform display bandwidth: 0.1 to 1.8 Hz (-3dB)
Alarms: User-selectable upper and lower respiration rate limits and apnea limit
Temperature
Number of channels: 1
Input specifications
Probe type: YSI Series 400
Temperature range: 0°C to 45°C (32°F to 113°F)
Resolution: ±0.1°C
Output specifications
Parameters displayed: TP
Accuracy: (independent of source) ±0.1°C
Alarms: User-selectable upper and lower limits
Noninvasive Blood Pressure
Measurement technique: Oscillometric
Displayed parameters: Systolic, diastolic, and mean pressures, pulse rate, time of last measurement
Measurement modes: Manual, auto, and stat in Adult ICU and OR modes; manual and auto in neonatal mode Heart rate detection: 30 to 300 beats per minute
Total cycle time: 20 to 40 seconds typical (dependent on heart rate and motion artifact) Automatic cycle times: 0 to 24 hours
Auto zero: Zero pressure reference prior to each cuff inflation
Tubing length: 12 feet adult, 8 feet neonatal
Automatic cuff deflation: Cycle time exceeding 3 minutes (90 seconds neonatal), power off, or cuff pressure exceeds 300 mmHg (+10%) adult, 150 mmHg (+10%) neonatal
Cuff sizes:
Disposable: Large adult, adult, small adult, pediatric, small pediatric, and infant
Reusable: Thigh, large adult, adult, child, and infant
Alarms: User-selectable upper and lower limits for systolic, diastolic, and mean pressures
Pulse Oximetry
Parameters monitored: Arterial oxygen saturation (SpO2) and peripheral pulse rate (PPR)
SpO2 range: 50 – 100%
PPR range: 20 – 250 beats per minute (� 3 beats per minute)
Accuracy: Actual accuracy depends on probe. Please reference manufacturer’s specifications.
SpO2: ±2% (70 – 100% SpO2) ±1 standard deviation ±3% (50 – 69% SpO2) ±1 standard deviation
PPR: ±3 beats per minute
Alarms: User-selectable upper and lower limits for SpO2 and PPR
Paper Recorder (Option)
Method: Thermal dot array
Horizontal resolution: 480 dots/in @ 25 mm/sec
Vertical resolution: 200 dots/in
Number of waveform channels: three
Paper width: 50 mm (1.97 in)
Paper length: 25 m (95 ft)
Paper speed: 0.1, 0.5, 1, 5, 10, 12.5, 25, and 50 mm/sec
Analog Output ECG
Gain: 1 V/mV ±10%
DC offset: ±100 mV (max)
Noise: <5 mV peak to peak dc to 300 Hz
Frequency response: 0.05 Hz to 100 Hz -0/+7 Hz
Internal Battery
Battery type: Nickel-cadmium (Ni-Cd)
Charge time: 1 to 4 hrs
Run time: 3 to 4 hrs
Environmental Specifications
Power requirements: 90-264 VAC 50/60 Hz 500 mA
Power consumption: 40 W (fully loaded)
Cooling: convection
Heat dissipation: 135 Btu/hr (max)
Operating Conditions
Ambient temperature: 10 to 40°C (50 to 104°F)
Relative humidity: 5 – 95% @ 40°C
Storage Conditions
(do not exceed):
Temperature: -25 to 70°C (-13 to 156°F)
Relative humidity: 15 to 95%
Physical Specifications
Height: 22 cm (8.5 in)
Depth: 20 cm (8 in)
Width: 27 cm (10.5 in)
Weight: 5.5 kg (12 lb) with all options