Drager: Narkomed GS

Features:

Weight (base unit without vaporizers or cylinders): 224 lbs (101.6 kg)
Dimensions: (W) 89.5 cm x (H) 130 cm x (D) 82 cm 35.2 x 51.2 x 32.3 inches)
Power Supply: 100-240 VAC, 50/60 Hz, 2.3 A max.
Battery (supports ventilator and monitor): > 45 min
Ventilator E-vent: Electronically controlled, electrically driven
Breathing Frequency: 4 to 60 bpm
Max. Minute Volume (MV): 25 L/min
Positive End-Expiratory Pressure (PEEP): 0-20 cmH2O
Inspiration/Expiration Ratio (Ti:Te): 4:1 to 1:4
Pressure Limiting (Pmax): 15-70 cmH2O
Tidal Volume (Vt): 20-1400 mL in Volume Control; 20-1100 mL in SIMV/PS
Inspiratory pause (Tip:Ti): 0-50%
SIMV Inspiratory Time (Tinsp): 0.3-4.0 sec
Inspiratory Pressure (Pinsp): PEEP + 5 to 65 cmH2O
Inspiratory Flow (InspFlow): 10-75 L/min in Volume and Pressure Control, 10-85 L/min in Pressure Support
Pressure Support Level (ΔPPS): PEEP + 3 to 20 cmH2O
Min. Frequency for Apnea-Ventilation (Freq. Min.): 3-20 bpm and “OFF”
Trigger: 2-15 L/min
Range of Fresh Gas Flow Indicators: 0.00 to 12.0 L/min
Total Fresh Gas Flow Meter: 0 to 10 L/min, calibrated with a mixture of 50 % O2 and 50 % N2O mixture
O2 Flush: at 87 psi (6 bar): max.75 L/min, at 41 psi (2.8 bar): min 25 L/min
Vaporizer Mount: Drager or Selectatec® mount
Serial Interface: 1 x RS-232 (standard), 1 x RS-232 (option)
Protocols: Vitalink and Medibus
Data Available for Export: All fresh gas flow, ventilation and O2 data
Volume of CO2 Absorber: 1.5 Liter, option: Drager medical’s consumable CLIC absorber
Volume of Entire compact Breathing System: 2.8 Liter + bag


Vetland Landmark VSA-2100

The small, stable, and versatile anesthesia solution. This device meets all of your anesthesia needs with a small footprint. It includes a 5-leg base with smooth casters and is very lightweight. These features promise one of the most stable products available for any use.

Features

  • Neat, balanced, compact design

  • Ships with a Drager Isoflurane Funnel Fill Vaporizer

  • Pop-off valve with thumb occlusion

  • Proven human quality FDA type valves

  • Best heat and moisture conserving coaxial absorber

  • 1030cc absorber is better

    • Less trapped volume

    • Less chance of “channeling”

    • Quicker anesthetic adjustments

  • Quick disconnect fresh gas outlet for non-rebreathing applications

  • Mayo tray standard

  • Back cover protects all tubing connections

  • 0-4 lpm oxygen flow control with protective stop

  • Corrosion proof construction

  • 5-leg base with lifetime caster replacements

Starter Kit (Required with new rental)

  • 1 Adult 22mm F circuit with 2L Breathing Bag

  • 1 Pediatric 15mm wye circuit with 1 L Breathing Bag

  • 1 Bag of CO2 absorbent (Litholyme)

  • 1 6-foot, 19mm, scavenger tubing to connect to F/Air

  • 1 19mm to 22mm adaptor for F/Air to mate up to Scavenger tubing